BXBSX - FREON 22

Product Identification

Product ID:FREON 22
MSDS Date:08/13/1992
FSC:6830
NIIN:01-382-5105
MSDS Number: BXBSX

Responsible Party
E I DUPONT DE NEMOURS & CO
1007 MARKET ST
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-9442

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE) (SARA

CAS: 75-45-6

RTECS: PA6390000

Fraction By Weight: 100%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


IN THE PRESENCE OF CERTAIN CONCENTRATIONS OF

RTECS: 9999999ZZ


VENTILATION SHOULD BE USED IN LOW OR ENCLOSED PLACES.

RTECS: 9999999ZZ


"FREON 22" SHOULD NOT BE MIXED W/AIR FOR LEAK

RTECS: 9999999ZZ


PRESENT W/HIGH CONCS OF AIR ABOVE ATMOSPHERIC PRESS.

RTECS: 9999999ZZ


ALSO BE AVOIDED.

RTECS: 9999999ZZ


OVEREXP. SKIN CONT W/LIQUID MAY CAUSE

RTECS: 9999999ZZ


CARDIOVASCULAR SYSTEM MAY HAVE INCREASED

RTECS: 9999999ZZ


RANGING FROM 5% TO 70% INCLUDE EFTS ON CNS,

RTECS: 9999999ZZ


BODY WT GAIN, & PARTIAL ANESTH. IN CHRONIC INHAL

RTECS: 9999999ZZ


SIGNIFICANT, INCREASE OF TUMORS IN MALE RATS, BUT

RTECS: 9999999ZZ


50000 PPM (V/V). FC-22 WAS MUTAGENIC IN BACTERIAL

RTECS: 9999999ZZ


NOT MUTAGENIC IN WHOLE ANIMAL ESSAYS. A SLIGHT, BUT

RTECS: 9999999ZZ


MALFORMATIONS, DECR FETAL WTS) HAS BEEN OBSERVED IN

RTECS: 9999999ZZ


OF FC-22, CONC WHICH WAS ALSO MATERNALLY TOXIC.

RTECS: 9999999ZZ


TO CONCEPTUS & POSES NO CARCIN HAZ WHEN EXPOSURES

RTECS: 9999999ZZ


PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB

RTECS: 9999999ZZ


ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE

RTECS: 9999999ZZ


ACUTELY OR CHRONICALLY EXPOSED TO CFC'S.

RTECS: 9999999ZZ


100 (WT).

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL OF HIGH CONCS OF VAP IS HARMFUL
& MAY CAUSE IRREGULARITIES, UNCONSCIOUSNESS/DEATH. INTENTIONAL
MISUSE/DELIBERATE INHAL MAY CAUSE DEATH WITHOUT WARNING. VAP
REDUCES OXYGEN AVAILABLE FOR BRTHG & I S HVR/AIR. LIQUID CONT CAN
CAUSE FRSTBT. ANIMAL DATA: TOXICITY DESCRIBED IN ANIMALS EXPOSED BY
INHAL TO CONCS (ING 9)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:OVEREXP TO VAPS BY INHAL MAY INCLUDE TEMPORARY
NERVS SYS DEPRESS W/ANESTH EFTS SUCH AS DIZZ, HDCH, CONFUSN,
INCOORD, & LOSS OF CONSCIOUSNESS. HIGHER EXPOS TO VAPS MAY CAUSE
TEMPORARY ALTERATION OF HEA RT'S ELEC ACTIVITY W/IRREGULAR PULSE,
PALPITATIONS/INADEQUATE CIRCULATION. FATALITY MAY OCCUR FROM GROSS
(ING 7)
Medical Cond Aggravated by Exposure:BECAUSE OF POSSIBLE DISTURBANCES OF
CARDIAC RHYTHM, CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD
ONLY BE CONSIDERED AS A LAST RESORT IN LIFE-THREATENING
EMERGENCIES.

First Aid

First Aid:INHAL: IF LGE CONCS ARE INHALED, IMMED REMOVE TO FRESH AIR.
KEEP PERS CALM. IF NOT BRTHG, GIVE ARTF RESP. IF BRTHG IS
DIFFICULT, GIVE OXYGEN. CALL MD. SKIN CONT: FLUSH W/WATER FOR 15
MIN. TREAT FOR FR OSTBT IF NEC BY GENTLY WARMING AFFECTEDAREA. IF
IRRIT IS PRESENT, CALL MD. EYES: IMMED FLUSH W/PLENTY OF WATER FOR
AT LEAST 15 MIN. CALL MD. INGEST: NOT CONSIDERED A POTENTIAL ROUTE
OF EXPOSURE.

Fire Fighting

Flash Point Method:TOC
Flash Point:NONE
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
EXTINGUISHANT FOR OTHER BURNING MATERIAL IN AREA IS SUFFICIENT TO
STOP BURNING.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESSURE DEMAND SCBA &
FULL PROT EQUIP . USE WATER SPRAY/FOG TO COOL CONTAINERS.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCLUDE
CHLORIDES, FLUORIDES & PHOSGENE . OTHER BURNING MATLS MAY CAUSE
HCFC 22 TO BURN WEAKLY. CHLORODIFLUOROMETHANE (SUP DAT)

Accidental Release

Spill Release Procedures:NOTE: REVIEW FIRE & EXPLOS HAZ & SFTY PREC
BEFORE PROCEEDING W/CLEAN UP. USE APPROP PERSONAL PROT EQUIP DURING
CLEAN UP. VENT AREA, ESPECIALLY LOW/ENCLOSED PLACES WHERE HEAVY
VAPS MIGHT COLLECT. REMOV E OPEN FLAMES. USE SCBA FOR LGE
SPILLS/RELEASES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN CLEAN, DRY AREA. DO NOT HEAT
ABOVE 52C (125F).
Other Precautions:NO SMKNG IN AREA OF USE. DO NOT USE IN GEN VICIN OF
ARC WELDING, OPEN FLAMES/HOT SURFS. HEAT &/UV RADIA MAY CAUSE FORM
OF CHLORIDES, FLUORIDES &/PHOSGENE . USE W/SUFFICIENT VENT TO KEEP
EMPLOYEE EXPOS BELOW RECOMMENDED LIMITS. (ING 4)

Exposure Controls

Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT. USE
NIOSH/MSHA APPROVED SCBA WHEN A LARGE RELEASE OCCURS.
Ventilation:NORM VENT FOR STANDARD MFG PROC IS GEN ADEQ. LOC EXHAUST
SHOULD BE USED WHEN LARGE AMOUNTS ARE RELEASED. MECH (ING 3)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS.
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD: HALIDES, PHOSGENE . EXPLO HAZ: IS NOT FLAM AT AMBIENT
TEMPS & ATMOSPHERIC PRESS. HOWEVER IT HAS BEEN SHOWN IN TESTS TO BE
COMBUST AT PRESS AS LOW AS 60 PSIG AT AMBIENT TEMP WHEN MIXED
W/AIR AT CONCS OF 65 VOL & AIR. EXPTL DATA HAVE ALSO BEEN REPORTED
WHICH INDICATE COMBUST OF "FREON" 22 (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:-41F,-41C
Vapor Pres:151 PSIG
Vapor Density:3.03
Spec Gravity:1.194
pH:NEUT
Evaporation Rate & Reference:>1
Solubility in Water:0.30 WT % @ 25C
Appearance and Odor:CLEAR, COLORLESS LIQUEFIED GAS WITH SLIGHT ETHEREAL
ODOR
Percent Volatiles by Volume:ING 20

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS (POWDERED AL, ZN, BE, ETC.).
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:HIGH TEMPS (OPEN FLAMES, GLOWING METAL
SURFS, ETC.) FORMING HYDROCHLORIC & HYDROFLUORIC ACIDS, & POSS
CARBONYL (SUP DAT)

Disposal

Waste Disposal Methods:COMPLY WITH FEDERAL, STATE, AND LOCAL
REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE
DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.